Molex, a global electronics leader and connectivity innovator, has published a report that examines thermal management pitfalls and possibilities as data centre architects and operators strive to balance high-speed data throughput requirements with the impacts of growing power density and the need for heat dissipation on critical servers and interconnect systems.
Molex’s In-Depth Report of Thermal Management Solutions for I/O Modules addresses the limitations of legacy approaches for thermal characterisation and management and explores new innovations in server and optical module cooling to better support 112G and 224G connectivity.
“As demand for faster, more efficient data processing and storage continues to rise rapidly, so does the heat generated by the high-performance servers and systems needed to scale generative AI applications and support the transition from 112 Gbps PAM-4 to 224 Gbps PAM-4,” said Doug Busch, VP and GM, Enabling Solutions Group, at Molex. “The integration of optical connectivity and optical modules, applied with new cooling technologies, will optimise airflow and thermal management within next-gen data centers. Molex is driving innovations in thermal management across both copper and optical platforms, as well as within our power management products, to help our customers improve system cooling capabilities and enhance energy efficiency within next-gen data centers.”
Shift to 224 Gbps PAM-4 Shines Light on Creative Liquid Cooling
The move to 224 Gbps PAM-4 interconnects between servers and network infrastructure represents doubling the per-lane data rate. Power consumption is also surging, with optical modules alone reaching as high as 40W over long-range coherent links, up from 12W just a few years ago, representing nearly a 4X increase in power density.
In this informative report, Molex explores the latest in air cooling, along with the integration of creative liquid cooling solutions within existing form factors to address increased power and thermal demands on I/O modules. Direct-to-chip liquid cooling, immersion cooling, and the role of passive components to enhance active cooling are addressed. The report also delineates cooling methods that may be most effective for accommodating power demands in chips and I/O modules that scale to high levels.
To solve persistent challenges in cooling pluggable I/O modules, Molex features a liquid cooling solution, called “integrated floating pedestal.” In this scenario, each pedestal that contacts the module is spring-taught and moves independently, allowing implementation of a single cold plate to different 1xN and 2xN single row and stacked cage configurations.
For example, this solution for a 1×6 QSFP-DD module utilizes six independently moving pedestals which can compensate for varying port stack heights while ensuring seamless thermal contact. As a result, heat flows directly from the module generating heat to the pedestal over the shortest possible conduction path to minimise thermal resistance and maximise heat transfer efficiency.
Additionally, the Molex report outlines the inherent costs and risks associated with immersion cooling, which offers highly effective thermal cooling that exceeds roughly 50kW per rack but requires a complete overhaul of a data center’s architecture.
Molex Drop Down Heat Sink (DDHS) Technology
Beyond liquid cooling, Molex’s In-Depth Report of Thermal Management Solutions for I/O Modules details advanced approaches to module design and thermal characterisation poised to transform the performance of high-speed network interconnects.
For I/O specifically, new solutions can be integrated into servers and switches for greater levels of heat sinking without compromising reliability. To that end, the report describes an innovative Molex Drop Down Heat Sink (DDHS) solution that maximises the heat transfer capability of a traditional riding heat sink while minimising metal-to-metal contact, which can create wear-and-tear on components.
Through the DDHS, Molex replaces current riding heat sinks with a solution that eliminates direct contact between the optical module and thermal interface material (TIM) for a simpler and more durable installation without friction or piercing.
As a result, Molex’s DDHS allows successful TIM implementation for more than 100 insertion cycles. This reliable heat management solution fits within standard module and rackmount form factors while effectively cooling higher power modules and improving overall power efficiency.
Future of Optical Module Cooling
As an active participant in the Open Compute Project (OCP) and its Cooling Environments project, Molex is collaborating with other industry leaders to develop next-gen cooling technologies that meet the evolving thermal management needs of today’s most demanding data centre environments.
Archive
- October 2024(44)
- September 2024(94)
- August 2024(100)
- July 2024(99)
- June 2024(126)
- May 2024(155)
- April 2024(123)
- March 2024(112)
- February 2024(109)
- January 2024(95)
- December 2023(56)
- November 2023(86)
- October 2023(97)
- September 2023(89)
- August 2023(101)
- July 2023(104)
- June 2023(113)
- May 2023(103)
- April 2023(93)
- March 2023(129)
- February 2023(77)
- January 2023(91)
- December 2022(90)
- November 2022(125)
- October 2022(117)
- September 2022(137)
- August 2022(119)
- July 2022(99)
- June 2022(128)
- May 2022(112)
- April 2022(108)
- March 2022(121)
- February 2022(93)
- January 2022(110)
- December 2021(92)
- November 2021(107)
- October 2021(101)
- September 2021(81)
- August 2021(74)
- July 2021(78)
- June 2021(92)
- May 2021(67)
- April 2021(79)
- March 2021(79)
- February 2021(58)
- January 2021(55)
- December 2020(56)
- November 2020(59)
- October 2020(78)
- September 2020(72)
- August 2020(64)
- July 2020(71)
- June 2020(74)
- May 2020(50)
- April 2020(71)
- March 2020(71)
- February 2020(58)
- January 2020(62)
- December 2019(57)
- November 2019(64)
- October 2019(25)
- September 2019(24)
- August 2019(14)
- July 2019(23)
- June 2019(54)
- May 2019(82)
- April 2019(76)
- March 2019(71)
- February 2019(67)
- January 2019(75)
- December 2018(44)
- November 2018(47)
- October 2018(74)
- September 2018(54)
- August 2018(61)
- July 2018(72)
- June 2018(62)
- May 2018(62)
- April 2018(73)
- March 2018(76)
- February 2018(8)
- January 2018(7)
- December 2017(6)
- November 2017(8)
- October 2017(3)
- September 2017(4)
- August 2017(4)
- July 2017(2)
- June 2017(5)
- May 2017(6)
- April 2017(11)
- March 2017(8)
- February 2017(16)
- January 2017(10)
- December 2016(12)
- November 2016(20)
- October 2016(7)
- September 2016(102)
- August 2016(168)
- July 2016(141)
- June 2016(149)
- May 2016(117)
- April 2016(59)
- March 2016(85)
- February 2016(153)
- December 2015(150)